Manufacturers of high performance spark plugs. Assorted machine tools and other metalworking processes create smoke and coolant mist.

Location: Irvine, CA

Installation Date: 2003

Type of Pollutant: Coolant Mist

Airflow: 3,000 CFM

Capture Method:
Source Capture. Most of the Machine Tools are completely enclosed. The Mist Collectors are ducted directly into the enclosure, thus putting the enclosure under a negative pressure to remove the coolant mist.
|
 |

Filtration System:
Media Style Air Cleaning System. Combination of washable Aluminum Mesh Prefilters and 95% Efficient Bag Filters remove both the large droplet size particles, as well as the fine mist.
|