Case Study 9

Manufacturers of precision parts and components for the Gas Turbine and Jet Engine markets. Parts are brought in from the field and repaired. Parts are coated with a Metal Spraying operation that creates a great deal of fine smoke and dust.


Location: San Diego, CA

Installation Date: 1998

Type of Polutant: Thermal Spraying Smoke and Dust

Airflow: 20,000 cfm


Capture Method:
Enclosure Method. All the parts that are going to be coated or sprayed are placed in a completely enclosed booth. The booth is equipped with a Backdraft Slotted Hood, to pull the smoke and dust back, away from the worker's breathing zone.


Filtration System:
A Self-Cleaning (64) Cartridge Dust Collection System with an Unpowered Cyclone that acts as a Spark Arrestor is installed. Unit is complete with Explosion Relief Panels and Sprinker Taps as required by the San Diego Fire Authority.